位置:首页 >> 期刊文章
|
摘要:
|
概述了钢筋混凝土阴极保护所使用阳极胶结材料的发展、组成、特点及适用范围,针对各自应用中存在的问题指出需要加以改进的方面,为研发新的性能优良的阳极胶结材料提供借鉴和指导。
|
This paper summarized the development,component,characteristic and applicable scope of anode cementation materials,which were used for cathodic protection in reinforced concrete.Based on the existing problems by applications,the aspects to be improved were indicated.It can provide references and directions for studying new fine performance anode cementation materials.
|
基金项目:
|
交通部西部重点项目(200631822302-02)
|
作者简介:
|
|
参考文献:
|
[1]黄明,沈德建.海洋环境下混凝土中钢筋的防腐蚀设计[J].混凝土,2006,(11):13-15.
[2]葛燕,朱锡昶.氯化物环境钢筋混凝土的腐蚀和牺牲阳极保护[J].水利水电科技进展,2005,25(4):67-70.
[3]孟繁强,陈向上,刘斌,等.用阴极保护防止混凝土结构的钢筋腐蚀[J].腐蚀与防护,2003,24(7):297-299.
[4]Cramer S D,Covino Jr B S,Bullard S J,et al.Corrosion Prevention and Remediation Strategies for Reinforced Concrete Coastal Bridges[J].Cement and Concrete Composites,2002,24(1):101-117.
[5]Page C L,Sergi G.Developments in Cathodic Protection Applied to Reinforced Concrete[J].Journal of Materials in Civil Engineering,2000,12(1):8-15.
[6]杜荣归,黄若双,赵冰,等.钢筋混凝土结构中阴极保护技术的应用现状及研究进展[J].材料保护,2003,36(4):11-14.
[7]Mietz J,Fischer J,Isecke B.Cathodic Protection of Steel-Rein-forced Concrete Structures-Results from 15 Years′Experience[J].Materials Performance,2001,40(12):22-26.
[8]Hassanein A M,Glass G K,Buenfeld N R.Protection Current Distribution in Reinforced Concrete Cathodic Protection Systems[J].Cement and Concrete Composites,2002,24(1):159-167.
[9]葛燕,朱锡昶.钢筋混凝土阴极保护和阴极防护技术的状况与进展[J].工业建筑2004,34(5):18-20.
[10]李守本.聚合物导电复层的研究[J].材料开发与应用,1999,14(4):35-38.
[11]Pedeferri P.Cathodic Protection and Cathodic Prevention[J].Construction and Building Materials,1996,10(5):391-402.
[12]Jennifer L K,Darwin D,Locke C E.Evaluation of Corrosion Protection Methods for Reinforced Concrete Highway Structures[R].University of Kansas Center for Research,2000.
[13]邱富荣,柯朝宗,许世力,等.海洋钢筋混凝土构筑物导电涂层阴极保护系统[J].腐蚀科学与防护技术,1992,4(1):59-62.
[14]洪定海,范卫国,罗德宽,等.海工钢筋混凝土上部结构外加电流阴极保护技术的初步研究(I)[J].腐蚀与防护,1990,11(4):197-202.
[15]叶青,胡国君,张泽南.掺石墨水泥基导电材料的物理性能研究[J].硅酸盐通报,1995,(6):37-40.
[16]王伟,季明棠.钢筋混凝土构筑物牺牲阳极保护研究进展[J].海洋科学,2001,25(5):18-20.
[17]Hartt W H.Analytical Evaluation of Galvanic Anode Cathodic Protection Systems for Steel in Concrete[J].Corrosion,2002,58(6):513-518.
[18]Whitmore D,Abbott S.Using Humectants to Enhance the Perfor-mance of Embedded Galvanic Anodes[C]//Proc NACE Corrosion.2003:3 301.
[19]Kessler R J,Powers R G,Lasa I R.An Update on the Long Term Use of Cathodic Protection of Steel Reinforced Concrete Marine Structures[C]//Proc NACE Corrosion.2002:2 254.
[20]Bennett J E,Firlotte C.Zinc/hydrogel System for Cathodic Pro-tection of Reinforced Concrete Structures[J].Materials Perfor-mance,1997,36(3):14-20.
[21]Kessler R J,Powers R G,Lasa I R.Zinc Sheet Anodes with Con-ductive Adhesive for Cathodic Protection[J].Materials Perfor-mance,1998,37(1):12-16.
[22]Dykstra B G,Wehling J E,Piazza J L II.Cathodic Protection of Steel Reinforced Concrete Structures Using a Galvanic Zinc Hy-drogel System[C]//57th Annual Conference&Exposition of Cor-rosion.Colorado,USA,2002:2 710-2 722.
[23]Gerardo G C,Donald R J.Evaluation of Anodes for Galvanic Ca-thodic Prevention of Steel Corrosion in Prestressed Concrete Pilesin Marine Environments in Virginia[R].VTRC 00-R3,Virginia Transportation Research Council,1999.
[24]Leng D L.Zinc Mesh Cathodic Protection Systems[J].Material Performance,2000,39(8):28-33.
[25]Richard J K,Rodney G P,Lasa I R.Zinc Mesh Anodes Cast into Concrete Pile Jackets[J].Materials Performance,1996,35(12):11-15.
[26]Kessler R J,Powers R G,Lasa I R.Polypropylene Fiber Rein-forced Concrete in Cathodic Protection Applications[C]//Proc NACE Corrosion,2004:4 342.
[27]Whitmore D,Abbott S.Embedded Galvanic Anodes Neutralizethe“Ring-Anode”Effect by Controlling Corrosion of Reinforcing Steel on a Local Scale[C]//17th Annual International Bridge Con-ference and Exhibition.Pennsylvania,USA,2000:36-40.
[28]Bennett J E,Talbot C.Extending the Life of Concrete Patch Re-pair with Chemically Enhanced Zinc Anodes[C]//Proc NACE Cor-rosion,2002:2 255.
[29]Bennett J E.Improvement in Cathodic Protection System:Euro-pean,1470266[P].2004-10-27.
[30]Bennett J E,McCord W T.Performance of Zinc Anodes Used to Extend the Life of Concrete Patch Repair[C]//Proc NACE Corro-sion.2006:6 331.
[31]Holcomb G R,Covino B S,Russell J H,et al.Humectant Use in the Cathodic Protection of Reinforced Concrete[J].Corrosion,2000,56(11):1 140-1 157.
[32]Jordan L C,Page C L.Mortars for Encapsulating Sacrificial Zinc Anodes in Reinforced Concrete[J].Materials and Corrosion,2003,54(6):387-393.
|
服务与反馈:
|